banner
Home

Reliability Testing

Reliability Testing

  • Reliability Environmental Testing: A Comprehensive Guide(1)
    May 27, 2025
    Introduction Reliability testing is a critical process in the development and production of equipment, ensuring that devices meet specified performance standards under expected operating conditions. Depending on the test environment, reliability testing can be classified into laboratory testing and field testing. Laboratory reliability tests are conducted under controlled conditions, which may or may not simulate real-world scenarios, whereas field reliability tests are performed in actual operational environments.   Based on the objectives and stages of product development, reliability testing can be further divided into: Reliability Engineering Tests (including Environmental Stress Screening (ESS) and Reliability Growth Testing) – aimed at identifying and eliminating faults, typically conducted during the development phase. Reliability Statistical Tests (including Reliability Verification Tests and Reliability Measurement Tests) – used to validate whether a product meets reliability requirements or to estimate its reliability metrics, usually performed during development and production.   This article focuses on Reliability Statistical Testing, covering test procedures, methodologies, performance monitoring, fault handling, and reliability metric calculations. 1. General Test Plan and Requirements (1) Pre-Test Preparation Before conducting reliability testing, a Reliability Test Plan must be developed, leveraging existing test data to avoid redundancy. Key preparatory steps include: Equipment Readiness: Ensure that the device under test (DUT), test equipment, and auxiliary instruments are properly configured and calibrated. Environmental Stress Screening (ESS): The DUT should undergo ESS to eliminate early-life failures. Test Review: A pre-test review should confirm that all conditions are met for a valid test.   (2) Comprehensive Environmental Test Conditions The test environment should simulate real-world operational stresses, including: Stress Combination: Sequential simulation of major stresses encountered in actual use. Operating Conditions: The DUT should operate under typical workload and environmental conditions. Standard Compliance: Test conditions should align with technical standards or contractual requirements.   (3) Statistical Test Plans and Selection Two primary test plans are defined: Fixed-Time Truncated Test Plan: Suitable when precise test duration and cost estimation are required. Sequential Truncated Test Plan: Preferred when the producer’s and consumer’s risks (10%–20%) are acceptable, especially for high- or low-reliability devices or when sample sizes are small.   Sample Selection: The DUT must be randomly selected from a batch produced under identical design and manufacturing conditions. A minimum of two samples is recommended, though a single sample may be allowed if fewer than three units are available. 2. Types of Reliability Statistical Tests (1) Reliability Qualification Test Purpose: To verify whether the design meets specified reliability requirements. Key Aspects: Conducted under simulated operational conditions. Requires representative samples of the approved technical configuration. Includes test condition determination, fault classification, and pass/fail criteria.   (2) Reliability Acceptance Test Purpose: To ensure that mass-produced devices meet reliability standards before delivery. Key Aspects: Performed on randomly selected samples from production batches. Uses the same environmental conditions as qualification testing. Includes batch acceptance/rejection criteria based on test results.   (3) Reliability Measurement Test Purpose: To estimate reliability metrics such as failure rate (λ), mean time between failures (MTBF), and mean time to failure (MTTF). Key Aspects: No predefined truncation time; reliability can be estimated at any stage. Statistical methods are used to compute point estimates and confidence intervals.   (4) Reliability Assurance Test Purpose: An alternative to acceptance testing for highly reliable or mature products where conventional testing is impractical. Key Aspects: Conducted after ESS. Focuses on fault-free operation duration (t). Requires agreement between the manufacturer and customer. Conclusion Reliability environmental testing is essential for ensuring product durability and performance. By implementing structured test plans—whether qualification, acceptance, measurement, or assurance testing—manufacturers can validate reliability metrics, optimize designs, and deliver high-quality products. Environmental reliability testing can be achieved through environmental test chambers, which simulate real-world conditions to evaluate product performance, significantly reducing testing time and improving efficiency. Lab-Companion has over 20 years of expertise in manufacturing environmental test equipment. With extensive practical experience and on-site installation support, we help customers overcome real-world challenges in testing applications.
    Read More
  • User Guide for Environmental Test Equipment
    Apr 26, 2025
    1. Basic Concepts Environmental test equipment (often referred to as "climate test chambers") simulates various temperature and humidity conditions for testing purposes.                                                                                    With the rapid growth of emerging industries such as artificial intelligence, new energy, and semiconductors, rigorous environmental testing has become essential for product development and validation. However, users often face challenges when selecting equipment due to a lack of specialized knowledge.   The following will introduce the basic parameters of the environmental test chamber, so as to help you make a better choice of products.   2. Key Technical Specifications (1) Temperature-Related Parameters 1. Temperature Range   Definition: The extreme temperature range in which the equipment can operate stably over long periods.   High-temperature range:  Standard high-temperature chambers: 200℃, 300℃, 400℃, etc.  High-low temperature chambers: High-quality models can reach 150–180℃. Practical recommendation: 130℃ is sufficient for most applications.   Low-temperature range: Single-stage refrigeration: Around -40℃. Cascade refrigeration: Around -70℃. Budget-friendly options: -20℃ or 0℃.                                         2. Temperature Fluctuation   Definition: The variation in temperature at any point within the working zone after stabilization.   Standard requirement: ≤1℃ or ±0.5℃.   Note: Excessive fluctuation can negatively impact other temperature performance metrics.   3. Temperature Uniformity   Definition: The maximum temperature difference between any two points in the working zone.   Standard requirement: ≤2℃.   Note: Maintaining this precision becomes difficult at high temperatures (>200℃).   4. Temperature Deviation   Definition: The average temperature difference between the center of the working zone and other points.   Standard requirement: ±2℃ (or ±2% at high temperatures).   5. Temperature Change Rate   Purchasing advice: Clearly define actual testing requirements. Provide detailed sample information (dimensions, weight, material, etc.). Request performance data under loaded conditions.(How many produce you going to test once?) Avoid relying solely on catalog specifications.   (2) Humidity-Related Parameters 1. Humidity Range   Key feature: A dual parameter dependent on temperature.   Recommendation: Focus on whether the required humidity level can be maintained stably.   2. Humidity Deviation   Definition: The uniformity of humidity distribution within the working zone.   Standard requirement: ±3%RH (±5%RH in low-humidity zones).   (3) Other Parameters 1. Airflow Speed   Generally not a critical factor unless specified by testing standards.   2. Noise Level   Standard values: Humidity chambers: ≤75 dB. Temperature chambers: ≤80 dB.   Office environment recommendations: Small equipment: ≤70 dB. Large equipment: ≤73 dB.   3. Purchasing Recommendations Select parameters based on actual needs—avoid over-specifying. Prioritize long-term stability in performance. Request loaded test data from suppliers. Verify the true effective dimensions of the working zone. Specify special usage conditions in advance (e.g., office environments).
    Read More

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

home

products

WhatsApp

contact us