Email Us :
info@labcompanion.cn-
-
Requesting a Call :
+86 18688888286
This kind of test chamber consists of 3 zones: heat zone, cold zone and ambient zone. Three temperature zones can be simulated in the same chamber. This makes optimum stress conditions possible without having to move the test specimen.
Item No :
TS seriesOrder(MOQ) :
1Color :
WhiteLead Time :
35 working days
Model | TS-60 | TS-120 | TS-120P | TS-300 | TS-300P | |
Test space volume | L | 60 | 120 | 120 | 300 | 300 |
Mobile basket maximum load | Kg | 20 | 50 | 50 | 100 | 100 |
Test space size,Height×Width×Depth | mm | 370x380x430 | 410x470x650 | 410x470x650 | 610x770x650 | 610x770x650 |
Hot chamber temperature range | ℃ | +50~+220 | +50~+220 | +50~+220 | +50~+220 | +50~+220 |
Cold chamber temperature range | ℃ | -80~+70 | -80~+70 | -80~+70 | -80~+70 | -80~+70 |
Heating rate of hot chamber1 | K/min | 17 | 14 | 18 | 11 | 23 |
Cooling rate of cold chamber1 | K/min | 3.7 | 6.3 | 7.5 | 5 | 12 |
Cold chamber heating rate, single box operation1 | K/min | 3.2 | 2 | 2 | 1.5 | 1.5 |
Temperature stability2 | K | ±0.3~±1.0 | ±0.3~±1.0 | ±0.3~±1.0 | ±0.~±1.0 | ±0.3~±1.0 |
Temperature uniformity3 | K | ±0.5~±2.0 | ±0.5~±2.0 | ±1.0~±2.0 | ±0.5~±2.0 | ±1.0~±2.0 |
Hot/cold chamber transition time | sec | <10 | <10 | <10 | <10 | <10 |
Recovery time - temperature change test | min | <154 | <155 | <126 | <157 | <158 |
Hot chamber calibration value9 | ℃ | 125 | 125 | 125 | 125 | 125 |
Cold chamber calibration value9 | ℃ | -40 | -40 | -40 | -40 | -40 |
1According to IEC 60068-3-5. Increase the rate of temperature change by raising/lowering the hot/cold chamber temperature.
2Effective test space center point.
3Based on setting point: Temperature range -65℃ to +200℃
4MIL-STD-883E, method 1010.9, intensity class D, 4.5 kg lCs were distributed in two sample racks and measured in sample.
5MIL-STD-883J,method 1010.9,intensity class D,12 kg lCs were distributed in three sample racks and measured in sample.
6MIL-STD-883F,method 1010.9,intensity class D,20 kg ICs were distributed in three sample racks and measured in sample.
7MIL-STD-883J,method 1010.9,intensity class F,25 kg lCs were distributed in three sample racks and measured in sample.
8MIL-STD-883 F,method 1010.9,intensity class F,50 kg lCs were distributed in three sample racks and measured in sample.
9Ex-factory measurement
The above performance data is based on ambient temperature of +25℃, rated voltage of 400V/50Hz, no sample, no additional configuration and thermal compensation conditions.
Industrial Three-zone Thermal Shock Test Chamber
❉One chamber for everything
Using the damper shock method, 3 temperature zones (cold, hot, ambient) can be simulated in the same chamber. This makes optimum stress conditions possible without having to move the test specimen
❉Load test equipment easily
The basic version has an access port on the left with a 50 mm diameter for the placement of cables and connections. Movements of the loaded cables are avoided by the stationary test space.
❉Well distributed, efficiently tested
The test specimens can be distributed on up to seven insert grids, making an increased test throughput of up to 150 kg possible.
Temperature Three-zone Thermal Shock Test Chamber
Touch type programmable temperature and humidity controller
It is temperature and humidity programmable controller which equips with the general control, heating and cooling function by supporting high definition TFT-LCD touch screen and SD card.
Performance:
High accuracy
Precision control with 18bit A/D convertor
TEMP. : ±0.1% of full scale ±1 digit
HUMI. : ±1.0% of full scale ±1digit
Optimizing PID group
Precision control by 6 groups of TEMP./HUMI. and 3 group of temperature only
Specialized controller
As a specialized controller for temperature and humidity, synchronized control system with PT-PT, PT-DCV
Specialized humidity control
Humidity control algorithm implements a stable control according to the equipment size。
Heating cooling control
Configuration separated by display, control, and input / output board
Available to mount panel mount and VESA mount