banner
Home Thermal Shock Test Chamber

80L Three-Zone Thermal Shock Chamber CE ISO for Electronic Reliability Test

80L Three-Zone Thermal Shock Chamber CE ISO for Electronic Reliability Test

80L Three-Box Thermal Shock Chamber CE ISO Automotive Component Screening

This 80L thermal shock chamber features three zones: hot zone, cold zone and ambient zone. It simulates three temperature ranges from -70℃ to 200℃ within one unit, creating ideal stress conditions without transferring test samples.

  • Item No :

    TSL-80
  • Order(MOQ) :

    1
  • Product Origin :

    China
  • Color :

    white

80L Three-Zone Shock Chamber CE ISO for Semiconductor Stress Testing

Model   TSL-80 TSL-120
TSL-120P
TSL-300
TSL-300P
Test space volume L 70 120 120 300 300
Mobile basket maximum load Kg 20 50 50 100 100
Test space size,Height×Width×Depth mm 400x500x400 410x470x650 410x470x650 610x770x650 610x770x650
Hot chamber temperature range ℃ +50~+200 +50~+200 +50~+200 +50~+200 +50~+200
Cold chamber temperature range ℃ -70~+50 -70~+50 -70~+50 -70~+50 -70~+50
Heating rate of hot chamber1 ℃/min 3 3 3 3 3
Cooling rate of cold chamber1 ℃/min 1 1 1 1 1
Temperature stability2 ℃ ±0.3~±1.0 ±0.3~±1.0 ±0.3~±1.0 ±0.~±1.0 ±0.3~±1.0
Temperature uniformity3 ℃ ±0.5~±2.0 ±0.5~±2.0 ±1.0~±2.0 ±0.5~±2.0 ±1.0~±2.0
Hot/cold chamber transition time sec <10 <10 <10 <10 <10
Recovery time - temperature change test min <154 <155 <126 <157 <158
Hot chamber calibration value9 ℃ 125 125 125 125 125
Cold chamber calibration value9 ℃ -40 -40 -40 -40 -40

1According to IEC 60068-3-5. Increase the rate of temperature change by raising/lowering the hot/cold chamber temperature.

2Effective test space center point.

3Based on setting point: Temperature range -65℃ to +200℃

4MIL-STD-883E, method 1010.9, intensity class D, 4.5 kg lCs were distributed in two sample racks and measured in sample.

5MIL-STD-883J,method 1010.9,intensity class D,12 kg lCs were distributed in three sample racks and measured in sample.

6MIL-STD-883F,method 1010.9,intensity class D,20 kg ICs were distributed in three sample racks and measured in sample.

7MIL-STD-883J,method 1010.9,intensity class F,25 kg lCs were distributed in three sample racks and measured in sample.

8MIL-STD-883 F,method 1010.9,intensity class F,50 kg lCs were distributed in three sample racks and measured in sample.

9Ex-factory measurement

The above performance data is based on ambient temperature of +25℃, rated voltage of 400V/50Hz, no sample, no additional configuration and thermal compensation conditions.

 80L Three-Box Thermal Shock Chamber CE ISO Aerospace Parts Validation

❉One chamber for everything

Using the damper shock method, 3 temperature zones (cold, hot, ambient) can be  simulated in the same chamber. This makes optimum stress conditions possible  without having to move the test specimen

❉Load test equipment easily

The basic version has an access port on the left with a 50 mm diameter for  the placement of cables and connections. Movements of the loaded cables  are avoided by the stationary test space.

❉Well distributed, efficiently tested

The test specimens can be distributed on up to seven insert grids, making  an increased test throughput of up to 150 kg possible.

 

80L Three-Zone Shock Chamber CE ISO Controller 

It is temperature and humidity programmable controller which equips with the general control, heating and cooling function by supporting high definition TFT-LCD touch screen and SD card.

Performance:

High accuracy

Precision control with 18bit A/D convertor

TEMP. : ±0.1% of full scale ±1 digit

HUMI. : ±1.0% of full scale ±1digit

      Optimizing PID group

Precision control by 6 groups of TEMP./HUMI. and 3 group of temperature only

      Specialized controller

As a specialized controller for temperature and humidity, synchronized control system with PT-PT, PT-DCV

     Specialized humidity control

Humidity control algorithm implements a stable control according to the equipment size。

      Heating cooling control

Separated hardware

Configuration separated by display, control, and input / output board
Available to mount panel mount and VESA mount

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

Front of 80L Three-Box Thermal Shock Chamber
80L Three-Zone Thermal Shock Chamber CE ISO for Electronic Reliability Test

80L Three-Box Thermal Shock Chamber CE ISO Automotive Component Screening This 80L thermal shock chamber features three zones: hot zone, cold zone and ambient zone. It simulates three temperature ranges from -70℃ to 200℃ within one unit, creating ideal stress conditions without transferring test samples.

read More
temperature shock chamber
Two zone Thermal Shock Test Chamber

Two zone Thermal Test Chamber 【Introduction】 Environmental conditions have a great influence on the  functionality and reliability of the electronic components,  devices and systems. A normal temperature test is often  not sufficient to detect latent weak points as quickly as  possible. Samples must be subjected to multiple, shock like temperature changes. With thermal shock test  chamber extremely fast temperature changes  from –55 °C to +150 °C can be achieved. This helps you to reduce early failures and to increase the reliability of your  products. Reproducible, certified and under accelerated  conditions. 【Test Standard】 IEC 60068-2-14 Na MIL-STD-810H,  Method 503.7 MIL-STD-883L-1,  Method 1010.9 JASO D 014-4

read More
Three-room integrated unit
Three-zone Thermal Shock Test Chamber

Three-zone Thermal Shock Test Chamber This kind of test chamber consists of 3 zones: heat zone, cold zone and ambient zone. Three temperature zones can be simulated in the same chamber. This makes optimum stress conditions possible without having to move the test specimen.

read More
2 Boxes Basket Type Thermal Shock Test Chamber
Two-zone(Basket Type) Cold and Thermal Shock Test Chamber

Two-zone(Basket Type) Cold and Thermal Shock Test Chamber is a device designed to replicate a range of environmental conditions a product might face throughout its lifespan. It features two distinct compartments: one for hot and one for cold environments. The hot compartment is heated by a heating element, while the cold compartment is chilled by a refrigeration unit. Each box’s temperature is independently controlled, enabling the creation of various temperature scenarios. Products are placed inside and exposed to alternating hot and cold conditions to simulate thermal shock, which is especially critical for electronic components sensitive to temperature fluctuations. This chamber is also valuable for testing product durability under extreme temperatures, relevant for industries such as aerospace and automotive. In essence, the Two-zone(Basket Type) Cold and Thermal Shock Test Chamber is crucial for product testing and quality assurance, ensuring that items can endure the environmental stresses they will likely face in real-world applications.

read More
Two independent pre-cooling chambers
Two-zone Thermal Shock Test Chamber

Two-zone Thermal Shock Test Chamber Environmental conditions have a great influence on the  functionality and reliability of the electronic components,  devices and systems. A normal temperature test is often  not sufficient to detect latent weak points as quickly as  possible. Samples must be subjected to multiple, shock like temperature changes. With thermal shock test  chamber extremely fast temperature changes  from –55 °C to +150 °C can be achieved. This helps you to reduce early failures and to increase the reliability of your  products. Reproducible, certified and under accelerated  conditions.

read More

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

home

products

WhatsApp

contact us